Dimensions and Weights of Transformators With One and Two Phases

Power

A
B
C
D
E
Weight
40 VA
84 mm.
90 mm.
63 mm.
70 mm.
47 mm.
1.20 KG
50 VA
84 mm.
90 mm.
65 mm.
70 mm.
49 mm.
1.34 KG
65 VA
84 mm.
90 mm.
68 mm.
70 mm.
52 mm.
1.48 KG
75 VA
84 mm.
90 mm.
73 mm.
70 mm.
57 mm.
1.65 KG
100 VA
84 mm.
90 mm.
85 mm.
70 mm.
69 mm.
2.10 KG
120 VA
84 mm.
90 mm.
95 mm.
70 mm.
79 mm.
2.49 KG
160 VA
96 mm.
101 mm.
87 mm.
80 mm.
66 mm.
2.80 KG
200 VA
96 mm.
101 mm.
97 mm.
80 mm.
76 mm.
3.25 KG
250 VA
108 mm.
111 mm.
100 mm.
90 mm.
81 mm.
4.20 KG
300 VA
120 mm.
120 mm.
91 mm.
100 mm.
75 mm.
4.50 KG
400 VA
120 mm.
120 mm.
106 mm.
100 mm.
90 mm.
5.66 KG
500 VA
133 mm.
132 mm.
106 mm.
111 mm.
92 mm.
7.00 KG
630 VA
150 mm.
145 mm.
110 mm.
125 mm.
92 mm.
8.50 KG
750 VA
150 mm.
145 mm.
119 mm.
125 mm.
101 mm.
9.80 KG
1000 VA
171 mm.
154 mm.
127 mm.
143 mm.
105 mm.
13.00 KG
1250 VA
171 mm.
154 mm.
132 mm.
143 mm.
110 mm.
14.60 KG
1500 VA
171 mm.
154 mm.
142 mm.
143 mm.
120 mm.
16.50 KG
1750 VA
192 mm.
170 mm.
145 mm.
160 mm.
121 mm.
20.00 KG
2000 VA
192 mm.
170 mm.
150 mm.
160 mm.
126 mm.
21.00 KG
2500 VA
192 mm.
170 mm.
180 mm.
160 mm.
156 mm.
27.70 KG

Because the transformators over 2500 VA have been designing specially, no dimension is given.

Hole isolation (screw) is made in order to hold power loss of transfomators with one and two phases at minumum at all powers of 160 VA and over.

 

Dimensions and Weights of Transformators With Tree Phases

Power

A
B
C
Weight
300 VA
92 mm.
125 mm.
106 mm.
8.0 KG
500 VA
192 mm.
125 mm.
116 mm.
9.4 KG
1000 VA
246 mm.
155 mm.
120 mm.
16.0 KG
1500 VA
300 mm.
185 mm.
155 mm.
24.5 KG
2000 VA
300 mm.
185 mm.
170 mm.
28.5 KG
2500 VA
300 mm.
185 mm.
180 mm.
33.0 KG
3000 VA
300 mm.
185 mm.
200 mm.
36.7 KG
3500 VA
300 mm.
185 mm.
200 mm.
38.0 KG
4000 VA
300 mm.
185 mm.
165 mm.
39.3 KG
5000 VA
300 mm.
185 mm.
180 mm.
51.5 KG
7500 VA
360 mm.
300 mm.
200 mm.
78.0 KG
10000 VA
360 mm.
300 mm.
200 mm.
87.0 KG
15000 VA
420 mm.
350 mm.
220 mm.
123.0 KG
20000 VA
420 mm.
350 mm.
235 mm.
137.0 KG
25000 VA
480 mm.
400 mm.
250 mm.
89.0 KG
30000 VA
480 mm.
400 mm.
260 mm.
203.0 KG
35000 VA
480 mm.
400 mm.
275 mm.
228.0 KG
40000 VA
600 mm.
500 mm.
250 mm.
300.0 KG
50000 VA
600 mm.
500 mm.
250 mm.
330.0 KG
75000 VA
720 mm.
600 mm.
290 mm.
465.0KG
100000 VA
798 mm.
665 mm.
295 mm.

585.0 KG

Because the transformators over 100 KVA have been designing specially, no dimension is given.

Hole isolation (screw) is made in order to hold power loss of all the transfornators with three phases at minumum.

 

General Features of Transformator

Standarts : IEC EN 61558-1-2-6
Input Voltage : to 1000 V
Output Voltage : to 500 V
Isolation Material : IEC EN 60641-2
Isolation Class : B 120C °
Frequency : 50-60 Hz
Power :

to 50 KVA In land 2 Phases

Power : to 250 KVA in 3 Phase
Wrapping Wire : Only copper glazed bobin wire
Transformer Plate : With 1.7 w/kg loss 0.50 mm silica
Connections Ends : Optionally
Cooling : Natural (Air Cooling)
Heat in Load : to60C °
Ambiend Temperature : Between -15C ° and + 70C °
Storing Heat : Between -20C ° and + 70C °
Storing Life : 5 Years